We don't care what you think - this sensor is mind-boggling. Developed by the inventors of the renowned BioMuse, it captures EEG (brainwaves), EOG (eye movements) and facial EMG (muscle movements).
Use the BioWave with a wireless Wi-microSystem in all cases to operate conveniently without tether and ensure electrically safe operation (see application notes below).
Application examples
- Combines perfectly with the BioFlex and BioBeat. Become zen and still perform.
- Add intensity to your musical performance by tweaking your sound through frowns, winks and other histrionics. Or just let the brain waves do the work !
- For whole-body expression go bodysuit, capture all your joints' movements and express with all your extremities.
Combine with
BendMicro,
BendMini and
BendShort sensors from finger to toe.
Add a GForce3D-3 on your feet
and hands to capture kicks and punches.
A Hot will keep
you in check of your body temp. Top it all off with a
TouchGlove on both hands
to always be able to touch-control your performance, even when you're doing a handstand.
Technical specifications
Product |
BioWave sensor |
Version |
1.0 (June 2007) |
Sensing parameter |
skin surface voltage |
Sensing method |
galvanic |
Gain |
10,000 |
Bandwidth |
1 â 200 Hz with 60 Hz notch filter, 50 Hz notch available for European users |
Power supply |
4.75 to 5.25 V DC, mA |
Sensor dimensions |
183 x 26 x 10 mm (7.2 x 1.0 x 0.39 inch), electrode distance 62 mm (2.4 inch), total strap length 63 cm (25 inch) |
Weight |
60 g. (2.1 oz) incl. cable and strap |
Cable |
1.15 m (0.45 inch) shielded, red wire = power, black wire = ground, white wire = signal, maximum extension m ( ft) |
Connector |
male plug with a row of 3 pins spaced 2.54 mm (0.100 inch) |
Application notes |
The BioWave sensor is to be used only with extreme caution. It is intended for research purposes only and not intended for any medical purposes whatsoever.
- The BioWave sensor must only be plugged into a battery powered, wireless I-CubeX digitizer (eg. the Wi-microDig or Wi-miniDig) manufactured by Infusion Systems and not any other digitizer.
- The BioWave sensor must only be connected as shown in the diagram on the digitizer.
- The wireless I-CubeX digitizer used with the BioWave sensor must only be powered by a common 9V battery as used in consumer goods or an I-CubeX BatteryPack.
- Only I-CubeX sensors may be connected to the digitizer that is used for interfacing the BioWave.
- When using the BioWave sensor, I-CubeX products may not be connected in any way to the electrical power grid or any other high voltage source.
Any violation of these instructions nullifies any warranty (express or implied) and nullifies any liability or culpability (express or implied) of Infusion Systems Ltd.. Any violation of these instructions can result in electrocution, severe injury, or even death.
Using the sensor with the Wi-microSystem not only ensures electrically safe operation but also enables you to use the sensor without being tethered to your computer or MIDI device. |
|