− | == | + | ==MIDI STATUS (95, 60h)== |
− | This message contains the activation status of the USB-microDig running status. See the [[Firmware-73_Command- | + | This message contains the activation status of the USB-microDig running status, active sensing and sampling loop marking. See the [[Firmware-73_Command-094 |MIDI STATUS command]] for more information. |
− | The [BODY] of the | + | The [BODY] of the MIDI STATUS message is as follows: |
{| | {| | ||
− | | | + | |00000zyx: |
− | |x = 0; running status | + | |x = 0; MIDI running status enabled (channel voice MIDI messages only include a MIDI status byte when it changes) |
|- | |- | ||
| | | | ||
− | |x = 1; running status enabled | + | |x = 1; MIDI running status disabled (each channel voice MIDI message includes a MIDI status byte) |
+ | |- | ||
+ | | | ||
+ | |y = 0; MIDI active sensing disabled | ||
+ | |- | ||
+ | | | ||
+ | |y = 1; MIDI active sensing enabled | ||
+ | |- | ||
+ | | | ||
+ | |z = 0; Sampling interval marking disabled | ||
+ | |- | ||
+ | | | ||
+ | |z = 1; Sampling interval marking enabled | ||
+ | | | ||
+ | |- | ||
|} | |} |
Latest revision as of 04:45, 4 December 2017
MIDI STATUS (95, 60h)
This message contains the activation status of the USB-microDig running status, active sensing and sampling loop marking. See the MIDI STATUS command for more information.
The [BODY] of the MIDI STATUS message is as follows:
00000zyx: | x = 0; MIDI running status enabled (channel voice MIDI messages only include a MIDI status byte when it changes) | |
x = 1; MIDI running status disabled (each channel voice MIDI message includes a MIDI status byte) | ||
y = 0; MIDI active sensing disabled | ||
y = 1; MIDI active sensing enabled | ||
z = 0; Sampling interval marking disabled | ||
z = 1; Sampling interval marking enabled |