Difference between revisions of "Firmware-72 Command-032"
(Blanked the page) |
|||
Line 1: | Line 1: | ||
+ | ==MUTE (32, 20h)== | ||
+ | The MUTE command stops the sampling of all sensor inputs. It can be used in both modes of operation (stand-alone, host). After completion of the MUTE command, the USB-microDig does not send out any MIDI messages representing sensor values. After a RESET, the USB-microDig is un-muted by default. The MUTE command is a toggle. Sending it the first time after power-up mutes all active sensor inputs, sending it a second time un-mutes them, and so forth. The USB-microDig does not send out any messages upon completion of this command. | ||
+ | |||
+ | There is no [BODY] associated with this command. | ||
+ | |||
+ | Example: 240, 125, 0 {DEV}, 32 {MUTE}, 247 (F0h, 7Dh, 00h, 20h, F7h) |
Revision as of 05:00, 3 November 2015
MUTE (32, 20h)
The MUTE command stops the sampling of all sensor inputs. It can be used in both modes of operation (stand-alone, host). After completion of the MUTE command, the USB-microDig does not send out any MIDI messages representing sensor values. After a RESET, the USB-microDig is un-muted by default. The MUTE command is a toggle. Sending it the first time after power-up mutes all active sensor inputs, sending it a second time un-mutes them, and so forth. The USB-microDig does not send out any messages upon completion of this command.
There is no [BODY] associated with this command.
Example: 240, 125, 0 {DEV}, 32 {MUTE}, 247 (F0h, 7Dh, 00h, 20h, F7h)