Difference between revisions of "Firmware-72 Message-111"
(Created page with "==COM (111, 6Fh)== This message contains the COM port status of the USB-microDig. See the DUMP COM command for more information. The [BODY] of the COM message is as follows:...") |
|||
| Line 5: | Line 5: | ||
The [BODY] of the COM message is as follows: | The [BODY] of the COM message is as follows: | ||
| − | { | + | {| |
|00000xyz: | |00000xyz: | ||
|x = 0; DTR high | |x = 0; DTR high | ||
Latest revision as of 15:31, 3 November 2015
COM (111, 6Fh)
This message contains the COM port status of the USB-microDig. See the DUMP COM command for more information.
The [BODY] of the COM message is as follows:
| 00000xyz: | x = 0; DTR high |
| x = 1; DTR low | |
| y = 0; RTS low | |
| y = 1; RTS high | |
| z = 0; SUSP low (USB enabled) | |
| z = 1; SUSP high (USB disabled) |