Difference between revisions of "Firmware-72 Command-059"
(Created page with "==SEND OUTPUT INIT (59, 3Bh)== The SEND OUTPUT INIT command can be used to get the actuator output status. The command can be used in both host and stand-alone modes of opera...") |
|||
Line 15: | Line 15: | ||
Example: | Example: | ||
− | 240, 125, 0 {DEV}, 59 {SEND OUTPUT INIT}, 1 {yyy = 1}, 247 (F0h, 7Dh, 00h, 3Bh, 01h, F7h) | + | :240, 125, 0 {DEV}, 59 {SEND OUTPUT INIT}, 1 {yyy = 1}, 247 (F0h, 7Dh, 00h, 3Bh, 01h, F7h) |
Latest revision as of 15:48, 3 November 2015
SEND OUTPUT INIT (59, 3Bh)
The SEND OUTPUT INIT command can be used to get the actuator output status. The command can be used in both host and stand-alone modes of operation. Upon completion of the command the digitizer sends out the same message as the SET OUTPUT INIT command but with the command ID byte set to 59 (3Bh).
The [BODY] of the SEND OUTPUT INIT command consists of a single 7-bit byte with the following format:
0000xyyy: | x = 1; apply the command to all actuator outputs (yyy is ignored), ie. send 8 messages with the status for each actuator output |
yyy = [0..7]; actuator output number, where the first actuator output number = 0, and the last (8th) actuator output number = 7 |
Example:
- 240, 125, 0 {DEV}, 59 {SEND OUTPUT INIT}, 1 {yyy = 1}, 247 (F0h, 7Dh, 00h, 3Bh, 01h, F7h)