Difference between revisions of "Firmware-762 Message-111"
(Created page with "==LOW POWER AND COM (111, 6Fh)== This message contains the LED and serial (COM) port status of the USB-microDig. See the Firmware-762_Command-111 |LOW POWER AND COM command...") |
(No difference)
|
Latest revision as of 00:50, 7 March 2022
LOW POWER AND COM (111, 6Fh)
This message contains the LED and serial (COM) port status of the USB-microDig. See the LOW POWER AND COM command for more information.
The [BODY] of the LOW POWER message is as follows:
| 000d0xyz: | d = 0; LEDs on |
| d = 1; LEDs dimmed | |
| x = 0; DTR high | |
| x = 1; DTR low | |
| y = 0; RTS low | |
| y = 1; RTS high | |
| z = 0; SUSP low (USB enabled) | |
| z = 1; SUSP high (USB disabled) |