Difference between revisions of "Firmware-820 Command-111"
(Created page with "==LOW POWER (111, 6Fh)== This command sets the WiDig to dim the LEDs. Upon completion of the command the WiDig sends out the LOW POWER message....") |
|||
(One intermediate revision by the same user not shown) | |||
Line 6: | Line 6: | ||
{| | {| | ||
− | | | + | |01d00000: |
− | | | + | |d = 0; turn LEDs on |
|- | |- | ||
| | | | ||
− | | | + | |d = 1; dim LEDs |
|} | |} | ||
+ | |||
+ | Example: | ||
+ | |||
+ | To dim the LEDs the following message is sent. | ||
+ | |||
+ | :240, 125, 0 {DEV}, 111 {LOW POWER}, 96, 247 (F0h, 7Dh, 00h, 6Fh, 60h, F7h) |
Latest revision as of 01:01, 7 March 2022
LOW POWER (111, 6Fh)
This command sets the WiDig to dim the LEDs. Upon completion of the command the WiDig sends out the LOW POWER message. To get the LED status, send the command without body.
To set the LEDs, the [BODY] of the LOW POWER command should be as follows:
01d00000: | d = 0; turn LEDs on |
d = 1; dim LEDs |
Example:
To dim the LEDs the following message is sent.
- 240, 125, 0 {DEV}, 111 {LOW POWER}, 96, 247 (F0h, 7Dh, 00h, 6Fh, 60h, F7h)