==SET MODE (90, 5Ah)==
 
==SET MODE (90, 5Ah)==
  
This command sets the USB-microDig operation mode. When switching the mode of operation, all settings stored in non-volatile memory remain unchanged but all settings stored in volatile memory are re-initialized to the values stored in non-volatile memory. When switching to host mode the initial values for host mode are used (see the RESET command). When switching to stand-alone mode the initial values for stand-alone mode are used (see the RESET command). The default value for the mode of operation is stand-alone mode. Upon completion of the command the USB-microDig sends out the MODE message.
+
This command sets the USB-microDig operation mode. When switching the mode of operation, all settings stored in non-volatile memory remain unchanged but all settings stored in volatile memory are re-initialized to the values stored in non-volatile memory. When switching to host mode the initial values for host mode are used (see the RESET command). When switching to stand-alone mode the initial values for stand-alone mode are used (see the RESET command). The default value for the mode of operation is stand-alone mode. Upon completion of the command the USB-microDig sends out the [[Firmware-72_Message-091 |MODE message]].
 
   
 
   
 
The [BODY] of the SET MODE command is as follows:
 
The [BODY] of the SET MODE command is as follows:

Latest revision as of 17:14, 3 November 2015

SET MODE (90, 5Ah)

This command sets the USB-microDig operation mode. When switching the mode of operation, all settings stored in non-volatile memory remain unchanged but all settings stored in volatile memory are re-initialized to the values stored in non-volatile memory. When switching to host mode the initial values for host mode are used (see the RESET command). When switching to stand-alone mode the initial values for stand-alone mode are used (see the RESET command). The default value for the mode of operation is stand-alone mode. Upon completion of the command the USB-microDig sends out the MODE message.

The [BODY] of the SET MODE command is as follows:

0000000x: x = 0; host mode
x = 1; stand-alone mode