(Created page with "SET OUTPUT INIT (49, 31h) The SET OUTPUT INIT command sets the output status at power-up of the USB-microDig. If pulse is enabled/disabled with the SET OUTPUT command the pul...")
 
 
Line 29: Line 29:
 
In order to set the 2nd actuator output pulse width at power-up to 1.5ms, the following message is sent:
 
In order to set the 2nd actuator output pulse width at power-up to 1.5ms, the following message is sent:
  
240, 125, 0 {DEV}, 49 {SET OUTPUT INIT}, 97 {x = 1, p = 1, yyy = 1}, 64 {pulse width}, 247 (F0h, 7Dh, 00h, 31h, 61h, 40h, F7h)
+
:240, 125, 0 {DEV}, 49 {SET OUTPUT INIT}, 97 {x = 1, p = 1, yyy = 1}, 64 {pulse width}, 247 (F0h, 7Dh, 00h, 31h, 61h, 40h, F7h)
  
 
The pulse width is 1 + 64*0.008 = 1.5ms
 
The pulse width is 1 + 64*0.008 = 1.5ms
Line 35: Line 35:
 
In order to turn the same actuator output off and disable the pulse, the following message is sent:
 
In order to turn the same actuator output off and disable the pulse, the following message is sent:
  
240, 125, 0 {DEV}, 49 {SET OUTPUT INIT}, 1 {x = 0, p = 0, yyy = 1}, 0 {pulse width}, 247 (F0h, 7Dh, 00h, 31h, 01h, 00h, F7h)
+
:240, 125, 0 {DEV}, 49 {SET OUTPUT INIT}, 1 {x = 0, p = 0, yyy = 1}, 0 {pulse width}, 247 (F0h, 7Dh, 00h, 31h, 01h, 00h, F7h)
  
 
When disabling the pulse the pulse width value is ignored.
 
When disabling the pulse the pulse width value is ignored.

Latest revision as of 15:47, 3 November 2015

SET OUTPUT INIT (49, 31h)

The SET OUTPUT INIT command sets the output status at power-up of the USB-microDig. If pulse is enabled/disabled with the SET OUTPUT command the pulse is also enabled/disabled at power-up but this can be changed by using the SET OUTPUT INIT command. If the pulse is enabled and no pulse width value is set to use at power-up, the pulse width to use at power-up is set to zero. Enabling the pulse overrides the output on/off setting. The command can be used in both host and stand-alone modes of operation. All output settings are stored in both volatile and non-volatile memory. After a RESET of the USB-microDig, all outputs’ pulse statuses are retrieved from non-volatile memory whether in stand-alone mode or in host mode. Upon completion of the command the digitizer sends out the same command. To get the values stored in non-volatile memory, use the SEND OUTPUT INIT command.

The [BODY] of the SET OUTPUT INIT command consists of two 7-bit bytes with the following format:

0xp00yyy: x = 1; output on
x = 0; output off
p = 1; enable pulse
p = 0; disable pulse
yyy = [0..7]; actuator output number, where the first actuator output number = 0, and the last (8th) actuator output number = 7
0zzzzzzz: zzzzzzz = [0..127]; pulse width 1-2 ms (ie. steps of approx. 8 microseconds)

Example:

In order to set the 2nd actuator output pulse width at power-up to 1.5ms, the following message is sent:

240, 125, 0 {DEV}, 49 {SET OUTPUT INIT}, 97 {x = 1, p = 1, yyy = 1}, 64 {pulse width}, 247 (F0h, 7Dh, 00h, 31h, 61h, 40h, F7h)

The pulse width is 1 + 64*0.008 = 1.5ms

In order to turn the same actuator output off and disable the pulse, the following message is sent:

240, 125, 0 {DEV}, 49 {SET OUTPUT INIT}, 1 {x = 0, p = 0, yyy = 1}, 0 {pulse width}, 247 (F0h, 7Dh, 00h, 31h, 01h, 00h, F7h)

When disabling the pulse the pulse width value is ignored.