− | == | + | ==SET SOLO (32, 20h)== |
− | The | + | The SET SOLO command stops the processing of all sensor inputs except one so that the user can easily utilise the MIDI learn capability of a MIDI device. It is only effective in stand-alone mode. After completion of the SET SOLO command, the WiDig does not send out any MIDI messages representing sensor values except for one input. After a RESET, all active sensors are processed. |
+ | |||
+ | The [BODY] associated with this command: | ||
− | |||
Example: | Example: | ||
− | :240, 125, 0 {DEV}, 32 {TOGGLE MUTE}, 247 (F0h, 7Dh, 00h, 20h, F7h) | + | :240, 125, 0 {DEV}, 32 {TOGGLE MUTE}, 64, 247 (F0h, 7Dh, 00h, 20h, 40h, F7h) |
Revision as of 02:11, 11 December 2018
SET SOLO (32, 20h)
The SET SOLO command stops the processing of all sensor inputs except one so that the user can easily utilise the MIDI learn capability of a MIDI device. It is only effective in stand-alone mode. After completion of the SET SOLO command, the WiDig does not send out any MIDI messages representing sensor values except for one input. After a RESET, all active sensors are processed.
The [BODY] associated with this command:
Example:
- 240, 125, 0 {DEV}, 32 {TOGGLE MUTE}, 64, 247 (F0h, 7Dh, 00h, 20h, 40h, F7h)