Difference between revisions of "Firmware-770 Command-111"
Line 12: | Line 12: | ||
|d = 1; dim LEDs | |d = 1; dim LEDs | ||
|} | |} | ||
+ | |||
+ | Example: | ||
+ | |||
+ | To dim the LEDs (and get the serial port status) the following message is sent. | ||
+ | |||
+ | :240, 125, 0 {DEV}, 111 {LOW POWER}, 96, 247 (F0h, 7Dh, 00h, 6Fh, 60h, F7h) |
Latest revision as of 01:02, 7 March 2022
LOW POWER AND COM (111, 6Fh)
This command sets the USB-microDig to dim the LEDs and report its serial (COM) port status. Upon completion of the command the USB-microDig sends out the LOW POWER AND COM message. To get the LED and serial (COM) port status, send the command without body.
To set the LEDs, the [BODY] of the LOW POWER command should be as follows:
01d00000: | d = 0; turn LEDs on |
d = 1; dim LEDs |
Example:
To dim the LEDs (and get the serial port status) the following message is sent.
- 240, 125, 0 {DEV}, 111 {LOW POWER}, 96, 247 (F0h, 7Dh, 00h, 6Fh, 60h, F7h)