Difference between revisions of "Firmware-73 Message-111"
(Created page with "==COM (111, 6Fh)== This message contains the COM port status of the USB-microDig. See the DUMP COM command for more information. The [BODY] of the COM message is as follows:...") |
|||
Line 1: | Line 1: | ||
==COM (111, 6Fh)== | ==COM (111, 6Fh)== | ||
− | This message contains the COM port status of the USB-microDig. See the DUMP COM command for more information. | + | This message contains the COM port status of the USB-microDig. See the [[Firmware-73_Command-111 |DUMP COM command]] for more information. |
The [BODY] of the COM message is as follows: | The [BODY] of the COM message is as follows: |
Revision as of 04:58, 12 November 2016
COM (111, 6Fh)
This message contains the COM port status of the USB-microDig. See the DUMP COM command for more information.
The [BODY] of the COM message is as follows:
00000xyz: | x = 0; DTR high |
x = 1; DTR low | |
y = 0; RTS low | |
y = 1; RTS high | |
z = 0; SUSP low (USB enabled) | |
z = 1; SUSP high (USB disabled) |