==DUMP RES (12, 0Ch)==
 
==DUMP RES (12, 0Ch)==
  
The DUMP RES command can be used to retrieve the sampling resolution of a port when it is configured as an analog input. The command can be used in both host and stand-alone modes of operation. Upon completion of the DUMP RES command the USB-microDig sends out the same message as the [[Firmware-73 Command-002 |RES command]]. The DUMP RES command's response does not apply to ports that are configured for I2C sensors.
+
The DUMP RES command can be used to retrieve the sampling resolution of a port when it is configured as an analog input. The command can be used in both host and stand-alone modes of operation. Upon completion of the DUMP RES command the USB-microDig sends out the same message as the [[Firmware-73 Command-002 |RES command]]. The DUMP RES command's response does not apply to ports that are configured for digital I2C sensors.
  
 
The [BODY] of the RES command consists of a single 7-bit byte with the following format :
 
The [BODY] of the RES command consists of a single 7-bit byte with the following format :

Revision as of 04:27, 20 November 2016

DUMP RES (12, 0Ch)

The DUMP RES command can be used to retrieve the sampling resolution of a port when it is configured as an analog input. The command can be used in both host and stand-alone modes of operation. Upon completion of the DUMP RES command the USB-microDig sends out the same message as the RES command. The DUMP RES command's response does not apply to ports that are configured for digital I2C sensors.

The [BODY] of the RES command consists of a single 7-bit byte with the following format :

00000yyy: x = 1; apply the command to all ports (yyy is ignored), ie. send 8 messages with the status for each port
yyy = [0..7]; port number, where the first port number = 0, and the last (8th) input number = 7

Example:

In order to retrieve the resolution of port 2, configured as analog input, the following message is sent:

240, 125, 0 {DEV}, 12 {DUMP RES}, 2, 247 (F0h, 7Dh, 00h, 0Ch, 02h, F7h)