Difference between revisions of "Firmware-73 Command-107"

From I-CubeX Wiki
Jump to: navigation, search
(DUMP CONFIG (107, 6Bh))
 
Line 9: Line 9:
 
|1; configuration number
 
|1; configuration number
 
|-
 
|-
|00aaaaaa:
+
|00bbbaaa:
|aaaaaa = [0..63]; (virtual) sensor input number
+
|aaa = [0..7]; sensor input number
 +
|-
 +
|
 +
|bbb = [0..7]; virtual input number
 
|}
 
|}
  

Latest revision as of 00:31, 5 July 2017

DUMP CONFIG (107, 6Bh)

The DUMP CONFIG command is used to obtain the current settings of the USB-microDig. Upon completion of the command the USB-microDig sends out the CONFIG message.

The USB-microDig will send out the configuration of a USB-microDig sensor input when using the DUMP CONFIG command with the following [BODY]:

00000001: 1; configuration number
00bbbaaa: aaa = [0..7]; sensor input number
bbb = [0..7]; virtual input number

The Digitizer will send out the configuration of each USB-microDig binary output as well as the sample interval value when using the DUMP CONFIG command with a special value for the 2nd data byte in the [BODY]:

00000001: 1; configuration number
01111111: 127; actuator outputs flag