Difference between revisions of "Firmware-75 Command-090"

From I-CubeX Wiki
Jump to: navigation, search
(Created page with "==SET MODE (90, 5Ah)== This command sets the USB-microDig operation mode. When switching the mode of operation, all settings stored in non-volatile memory remain unchanged bu...")
 
(No difference)

Latest revision as of 21:03, 4 October 2017

SET MODE (90, 5Ah)

This command sets the USB-microDig operation mode. When switching the mode of operation, all settings stored in non-volatile memory remain unchanged but all settings stored in volatile memory are re-initialized to the values stored in non-volatile memory. When switching to host mode the initial values for host mode are used (see the RESET command). When switching to stand-alone mode the initial values for stand-alone mode are used (see the RESET command). The default value for the mode of operation is stand-alone mode. Upon completion of the command the USB-microDig sends out the MODE message.

The [BODY] of the SET MODE command is as follows:

0000000x: x = 0; host mode
x = 1; stand-alone mode