COM (111, 6Fh)
This message contains the COM port status of the USB-microDig. See the DUMP COM command for more information.
The [BODY] of the COM message is as follows:
00000xyz: | x = 0; DTR high |
x = 1; DTR low | |
y = 0; RTS low | |
y = 1; RTS high | |
z = 0; SUSP low (USB enabled) | |
z = 1; SUSP high (USB disabled) |