Difference between revisions of "Firmware-811 Command-109"
(Copied from Firmware-810 Command-109, revision 4333) |
|||
Line 1: | Line 1: | ||
==DUMP CONFIG RANGE (109, 6Dh)== | ==DUMP CONFIG RANGE (109, 6Dh)== | ||
− | The DUMP CONFIG RANGE command is used to obtain the current MIDI message output range settings of the WiDig. Upon completion of the command the WiDig sends out the [[Firmware- | + | The DUMP CONFIG RANGE command is used to obtain the current MIDI message output range settings of the WiDig. Upon completion of the command the WiDig sends out the [[Firmware-811_Message-107 |DUMP CONFIG message]] with 4-byte BODY. |
The WiDig will send out the configuration of a WiDig sensor input when using the DUMP CONFIG RANGE command with the following [BODY]: | The WiDig will send out the configuration of a WiDig sensor input when using the DUMP CONFIG RANGE command with the following [BODY]: |
Latest revision as of 16:15, 16 April 2019
DUMP CONFIG RANGE (109, 6Dh)
The DUMP CONFIG RANGE command is used to obtain the current MIDI message output range settings of the WiDig. Upon completion of the command the WiDig sends out the DUMP CONFIG message with 4-byte BODY.
The WiDig will send out the configuration of a WiDig sensor input when using the DUMP CONFIG RANGE command with the following [BODY]:
00000001: | 1; configuration number |
00bbbaaa: | aaa = [0..7]; sensor input number |
bbb = [0..7]; virtual input number |