DUMP CONFIG RANGE (109, 6Dh)

The DUMP CONFIG RANGE command is used to obtain the current MIDI message output range settings of the WiDig. Upon completion of the command the WiDig sends out the DUMP CONFIG message with 4-byte BODY.

The WiDig will send out the configuration of a WiDig sensor input when using the DUMP CONFIG RANGE command with the following [BODY]:

00000001: 1; configuration number
00bbbaaa: aaa = [0..7]; sensor input number
bbb = [0..7]; virtual input number