Difference between revisions of "Firmware-770 Message-095"
(Created page with "==MIDI STATUS (95, 60h)== This message contains the activation status of the USB-microDig running status, active sensing and sampling loop marking. See the Firmware-770_Com...") |
|||
Line 1: | Line 1: | ||
− | ==MIDI | + | ==MIDI CONFIG (95, 60h)== |
− | This message contains the activation status of the USB-microDig running status, active sensing and sampling loop marking. See the [[Firmware-770_Command-094 |MIDI | + | This message contains the activation status of the USB-microDig running status, active sensing and sampling loop marking. See the [[Firmware-770_Command-094 |MIDI CONFIG command]] for more information. |
− | The [BODY] of the MIDI | + | The [BODY] of the MIDI CONFIG message is as follows: |
{| | {| |
Latest revision as of 00:40, 7 March 2022
MIDI CONFIG (95, 60h)
This message contains the activation status of the USB-microDig running status, active sensing and sampling loop marking. See the MIDI CONFIG command for more information.
The [BODY] of the MIDI CONFIG message is as follows:
00000zyx: | x = 0; MIDI running status enabled (channel voice MIDI messages only include a MIDI status byte when it changes) | |
x = 1; MIDI running status disabled (each channel voice MIDI message includes a MIDI status byte) | ||
y = 0; MIDI active sensing disabled | ||
y = 1; MIDI active sensing enabled | ||
z = 0; Sampling interval marking disabled | ||
z = 1; Sampling interval marking enabled |