Difference between revisions of "Firmware-770 Message-111"
Line 1: | Line 1: | ||
==LOW POWER AND COM (111, 6Fh)== | ==LOW POWER AND COM (111, 6Fh)== | ||
− | This message contains the LED status of the USB-microDig. See the [[Firmware-820_Command-111 |LOW POWER AND COM command]] for more information. | + | This message contains the LED and serial (COM) port status of the USB-microDig. See the [[Firmware-820_Command-111 |LOW POWER AND COM command]] for more information. |
The [BODY] of the LOW POWER message is as follows: | The [BODY] of the LOW POWER message is as follows: |
Latest revision as of 00:49, 7 March 2022
LOW POWER AND COM (111, 6Fh)
This message contains the LED and serial (COM) port status of the USB-microDig. See the LOW POWER AND COM command for more information.
The [BODY] of the LOW POWER message is as follows:
000d0xyz: | d = 0; LEDs on |
d = 1; LEDs dimmed | |
x = 0; DTR high | |
x = 1; DTR low | |
y = 0; RTS low | |
y = 1; RTS high | |
z = 0; SUSP low (USB enabled) | |
z = 1; SUSP high (USB disabled) |