SEND TABLE (31, 1Fh)

The SEND TABLE command retrieves a lookup table with 1024 values that’s stored in non-volatile memory. The command can be used in both host and stand-alone modes of operation. Upon completion of the SEND TABLE command the USB-microDig sends out the same message as the TABLE ENTRY command, for each of the 1024 entries. This command is not available for digitizers with hardware v7.0 or lower.

The [BODY] of the SEND TABLE command contains a single 7-bit byte:

000nnnnn: nnnnn = [0..31]; table number

Example:

To download table 4 from a USB-microDig, send the following message:

240, 125, 0 {DEV}, 31 {SEND TABLE}, 4 {table number}, 247 (F0h, 7Dh, 00h, 1Fh, 04h, F7h)