Firmware-72 Message-111
COM (111, 6Fh)
This message contains the COM port status of the USB-microDig. See the DUMP COM command for more information.
The [BODY] of the COM message is as follows:
{- |00000xyz: |x = 0; DTR high |- | |x = 1; DTR low |- | |y = 0; RTS low |- | |y = 1; RTS high |- | |z = 0; SUSP low (USB enabled) |- | |z = 1; SUSP high (USB disabled) |}