TOGGLE MUTE (32, 20h)

The TOGGLE MUTE command stops the sampling of all sensor inputs. It can be used in both modes of operation (stand-alone, host). After completion of the TOGGLE MUTE command, the WiDig does not send out any MIDI messages representing sensor values. After a RESET, the WiDig is un-muted by default. The TOGGLE MUTE command is a toggle. Sending it the first time after power-up mutes all active sensor inputs, sending it a second time un-mutes them, and so forth. The WiDig does not send out any messages upon completion of this command.

There is no [BODY] associated with this command.

Example:

240, 125, 0 {DEV}, 32 {TOGGLE MUTE}, 247 (F0h, 7Dh, 00h, 20h, F7h)