EditorX Options
The Options section sets the sample interval, mode of operation and muting.
The sample interval can be set between a minimum and a maximum value, in milliseconds. The minimum value is 1 ms for all digitizers except the Digitizer, which has a 4 ms minimum. The maximum value is 16383 ms, ie. about 16 seconds.
The mode of operation can be set as standalone or host. EditorX sets a digitizer to standalone mode immediately after establishing a connection with a digitizer since EditorX can only configure the standalone mode settings of a digitizer.
Muting can be set to on or off, and configures the digitizer to stop sampling of all sensor inputs so that no data is output by the digitizer.