LOW POWER AND COM (111, 6Fh)

This command sets the USB-microDig to dim the LEDs and report its serial (COM) port status. Upon completion of the command the USB-microDig sends out the LOW POWER AND COM message. To get the LED and serial (COM) port status, send the command without body.

To set the LEDs, the [BODY] of the LOW POWER command should be as follows:

01d00000: d = 0; turn LEDs on
d = 1; dim LEDs

Example:

To dim the LEDs (and get the serial port status) the following message is sent.

240, 125, 0 {DEV}, 111 {LOW POWER}, 96, 247 (F0h, 7Dh, 00h, 6Fh, 60h, F7h)