A sensor for waving at your gear. Leave your fans in awe of your magic majestic gestures. Reaches up to 200 cm (79 inch) distance. Has linear behaviour, resulting in a smooth output that corresponds proportionally with your movement. A digital I2C sensor, that outputs high resolution, low-noise signals. To have a range up to 5.5 meter use the ReachFar.

Requires a USB-microDig running firmware v7.5 or higher.

Application examples

  1. Measurement of proximity of objects like hands or walls.
  2. Great for making that fake Theremin.
  3. Update your keyboard with this handy gadget.
  4. Combine with a TapTiled floor, some MoveOn and/or Advance and/or ReachFar sensors and make sure every move of your visitor has an effect. The Flash + SeeLaser combo adds a touch of diamond robbery feeling.
  5. Pamper your robot or toy car and combine with a Orient4D to detect approaches to and/or impacts with walls and what have you.
  6. Create a fancy control panel by combining Push sensors (Push, Push3D), Reach sensors, Slide sensors (eg. Slide-50, Slide-200, Slide-500, SlideRound, SlideWide), Touch sensors (Touch, TouchMicro-05 TouchMicro-10, TouchMini, TouchMiniOn, TouchStrip) and Turn sensors to name a few.

Technical specifications

Product ReachCloseD sensor
Version 1.0 (September 2017)
Sensing parameter distance, proximity
Sensing method modulated infra-red (940 nm) laser light reflectance sensor
Field of view 25 cone
Range 200 cm (79 inch) with indoor white (88% reflectance) target, 80 cm (31 inch) with outdoor grey (88% reflectance) target, 80 cm (31 inch) with indoor grey (17% reflectance) target, 50 cm (20 inch) with outdoor grey (17% reflectance) target. Target must cover full field of view.
Range accuracy (method 0 or 2) 4% with indoor white (88% reflectance) target at 120 cm, 7% with outdoor grey (88% reflectance) target at 60 cm, 7% with indoor grey (17% reflectance) target at 70 cm, 12% with outdoor grey (17% reflectance) target at 40 cm. Target must cover full field of view.
Range accuracy (method 1 or 3) 3% with indoor white (88% reflectance) target at 120 cm, 6% with outdoor grey (88% reflectance) target at 60 cm, 6% with indoor grey (17% reflectance) target at 70 cm, 9% with outdoor grey (17% reflectance) target at 40 cm. Target must cover full field of view.
Response time 20 ms (method 0 or 2), 200 ms (using method 1 or 3)
Power supply 4.75 to 5.25 V DC, 19 mA at 5 V
Sensor dimensions 25 x 12 x 5 mm (1.0 x 0.47 x 0.2 inch), incl. two 3 mm (0.1 inch) mounting holes
Operating temperature -20 to 70 C (-4 to 158 F)
Weight 12 g (0.42 oz), incl. cable
Cable 1.0 m (39 inch), shielded, red wire = power, black wire = ground, white wire = sensor output, maximum extension 20 m (66 ft)
Connector male plug with a row of 3 pins in a row spaced 2.54 mm (0.100 inch)
Software support

  • Our EditorX software allows you to configure the digitizer to process and map the sensor data of multiple sensors simultaneously.

Application notes
  1. Make sure the sensor is plugged into the digitizer with the red wire connected to power. Reversing the plug may cause damage to the sensor.
  2. Requires a USB-microDig running firmware v7.5 or higher.
  3. The default I2C address is 87 (0x57). Both I2C lines have 10 kOhm pull-up resistors.
  4. Our software enables you to use most features of this sensor. In EditorX, use the method parameter to set the sensor to output (method #0) distance with low accuracy 2 m range. (method #1) high accuracy 2 m range, (method #2) low accuracy 1 m range or (method #3) high accuracy 1 m range.
  5. Methods 1 and 3 measure with higher accuracy than methods 0 and 2. To achieve this the measurement takes about 200 ms whereas the lower accuracy methods 0 and 2 take about 20 ms.
  6. See also the ReachCloseD function description for more details about the various methods available in host and standalone mode.
  7. For more technical specs, and to find out how to access the sensor data in detail, please consult this datasheet.
  8. For best results when using a high accuracy range method, operate under low ambient light level conditions.
  9. The sensor will not measure the distance of objects placed behind glass (or other transparent surfaces) but the distance to the glass instead.
  10. To extend the cable, use ExtendCableD-01 and/or ExtendCableD-10.

This page was updated on Thursday 26 October 2017.
Comments by customers Write Review
There are currently no comments on this product.
Customers who bought this product also purchased
Advance-645 v1.1
Advance-645 v1.1
MoveAround v1.1
MoveAround v1.1
Light v1.3
Light v1.3
Flash v1.3.3
Flash v1.3.3
Wearability v1.0
Wearability v1.0
BioVolt v2.0
BioVolt v2.0
Product Search




Advanced Search
Comments more
Write ReviewWrite a comment on this product!
Support
New Customers

Need help?

Resources

Downloads

User forums

Linkedin group LinkedIn group

Facebook page Facebook page

Google+ page Google+ page