Firmware-72 Function-063

From I-CubeX Wiki
Jump to: navigation, search

THRU (63, 3Fh)

The THRU function does not convert the sensor value but provides a way to smooth the signal and/or view it before processing it with the EDIT CONFIG command.

The THRU function has the following parameter value FP2 that can be set with the FUNCTION command:

FP2

0m00yyyy: yyyy: 0; No smoothing
yyyy: [1..15]; Smoothing factor
m = 0; Monitor off
m = 1; Monitor on

When the monitor is enabled, the sensor value is output as a separate MIDI message after the smoothing function (if enabled) but before being processed as configured by the EDIT CONFIG command. The MIDI message is the same as set by the EDIT CONFIG command but, if note or controller messages are used, the note or controller number is incremented by one. If another MIDI message is used the MIDI channel is incremented by one.