excl. sales tax

A small, round touch sensor. Contact pressure provides continuous control. Responds to pressure from approx. 10 KPa (0.10 Kg/cm2, 1.5 PSI) to 981 KPa (10.0 Kg/cm2, 142 PSI) or a force of approx. 0.2 N (20 g, 0.04 lb) to 98 N (10 Kg, 22 lb) that's evenly applied across it's active area, a 5 mm (0.2 inch) diameter disk. View, calibrate, record, process and map the sensor data using our software (see below).

And look, it's part of a family. Here are all the versions we have available (note that some of these sensors have a different response curve):

Application examples

  1. Can be easily worn or applied to a variety of flat surfaces. Blow Laurie Anderson, Marillion and others away. Trigger those samples!
  2. Use as a touch sensor for a synthesizer.
  3. May be used to design your own fretless bass. Use for capturing slaps while the Slide-500 functions as your pitch controller. A GForce3D will help you accentuate your tones when you move the stem upright.
  4. Can be used in your custom wind instrument design. Use for buttons, while using a Slide-100 for octave control and a GForce3D to capture body movements.
  5. Create a fancy control panel by combining Push sensors (Push, Push2D), Reach sensors (Reach, ReachClose), Slide sensors (eg. Slide-50, Slide-200, Slide-500, SlideRound, SlideWide), Touch sensors (see above) and Turn sensors to name a few.

Technical specifications

Product TouchMicro-05 sensor
Version 1.2 (2006)
Sensing parameter contact pressure or force
Sensing technology zero-travel force sensitive resistor
Active area 5 mm (0.2 inch) diameter disk
Range approx. 10 KPa (0.10 Kg/cm2, 1.5 PSI) to 981 KPa (10.0 Kg/cm2, 142 PSI) or
approx. 0.2 N (20 g, 0.04 lb) to 98 N (10 Kg, 22 lb), evenly applied across active area
Repeatability 5% (max) for one sensor, 25% (max) across multiple sensors
Response time 1 to 2 ms (mechanical)
Output resistance more than 100 KOhm (at 0 N) to 200 Ohm (at 98 N) in parallel with 47 KOhm
Calibration (force applied evenly across active area)
N Kg lb Voltage (use 5 V power supply) 7-bit MIDI value (use 'no processing' editor preset)
0 0 0 0.00 0
0.98 0.10 0.22 2.36 60
9.8 1.0 2.2 4.61 117
98 10 22 5.00 127
Calibration (force applied per unit of active area)
KPa PSI Voltage (use 5 V power supply) 7-bit MIDI value (use 'no processing' editor preset)
0 0 0.00 0
49.6 7.20 2.36 60
496 72.0 4.61 117
4964 7200 5.00 127
Power supply 1.0 to 10 V DC, 0.1 mA at 5 V
Operating temperature -20 to 100 °C (-4 to 212 °F)
Dimensions 8 mm (0.3 inch) diameter x 0.5 mm (0.02 inch) thick disk
Mounting adhesive disk
Cable 1.0 m (39 inch), shielded, red wire = power, black wire = ground, white wire = sensor output, extendable at least 100 m (328 ft) with ExtendCableD-10
Connector male 1x4 plug with 3 pins in a row spaced 2.54 mm (0.100 inch)
Weight 15 g (0.5 oz), incl. cable
Software support
  • Our SensePlay software is a very easy way to quickly map sensor data to (sequences of) sounds, images and videos using a drag & drop user interface.
  • Our EditorX software allows you to configure the digitizer to process and map the sensor data of multiple sensors simultaneously.
  • Our Link software allows you to receive the sensor data from the digitizer and use your computer to view, calibrate, record, process and map the sensor data of multiple sensors simultaneously.
  • Our SensorX software allows you to receive the sensor data from the digitizer and use your computer to view, calibrate, record, process and map the data of a single sensor.

Application notes
  1. Please note that calibration of the sensor requires careful attention to detail since they behave differently near the extremes of the usable range. The sensor behaves as a force sensor within the specified range but may not behave like a force sensor beyond this range. It is merely documented as a saturation effect above the range, meaning that sensitivity changes with force, and as a threshold effect below the range, which behaviour may be hard to repeat or even random.
  2. To obtain reliable results, the force has to be applied evenly across the active surface area of the sensor. Using a finger to calibrate or to measure how much force you exert is very unreliable unless you at least use a flat rigid object between the finger and the sensor.
  3. If the sensor shows a non-zero value when no force is applied, flatten the sensor between two flat objects for a few days. Any bending of the sensor may result in a non-zero at-rest value. Store sensor in flat position for best results.
  4. Using adhesive to attach the sensor may result in a non-zero value when no force is applied

This page was updated on Wednesday 20 October 2021.
Comments by customers Write Review
There are currently no comments on this product.
Customers who bought this product also purchased
MoveOn v1.8
MoveOn v1.8
AngleD v1.2
AngleD v1.2
EncloseSensor v1.0
EncloseSensor v1.0
Angle v1.0
Angle v1.0
EncloseMini v1.0
EncloseMini v1.0
PiShield v1.0
PiShield v1.0
Product Search




Advanced Search
Comments more
Write ReviewWrite a comment on this product!
Support
New Customers

Need help?

Resources

Downloads

User forums

Linkedin group LinkedIn group

Facebook page Facebook page