Product |
Air2D sensor |
Version |
1.1 (August 2021) |
Sensing parameter |
barometric air pressure and ambient temperature |
Sensing method |
piezo-resistive MEMS sensor |
Pressure range |
10 to 1200 mbar (1 to 120 kPa) |
Pressure accuracy |
± 2.5 mbar (0.25 kPa), at -20 to +85 ºC, 450 to 1100 mbar (45 to 110 kPa) |
Pressure resolution |
0.065 to 0.012 mbar (6.5 to 1.2 Pa), corresponding to increasing oversampling ratio |
Pressure response time |
0.5 to 8 ms, corresponding to increasing oversampling ratio |
Temperature range |
-40 to +85 ºC (-40 to +185 ºF) |
Temperature accuracy |
0.8 ºC (1.4 ºF) |
Temperature resolution |
less than 0.01 ºC (0.02 ºF) |
Altitude range (calculated) |
-1450 to +25921 m (-4757 to +85043 ft) |
Altitude accuracy (calculated) |
0.1 m (0.3 ft) |
Dimensions |
20 x 15 x 5 mm (0.78 x 0.39 x 0.2 inch) |
Mounting |
one 3.15 mm (0.124 inch) mounting hole |
Cable |
1.0 m (39 inch), shielded, red wire = power, black wire = ground, grey wire = I2C data (SDA), white wire = I2C clock (SCL), extendable at least 0 m (0 ft) with ExtendCableD-01 |
Connector |
male 1x4 plug with a row of 4 pins spaced 2.54 mm (0.100 inch) |
Weight |
7 g (0.2 oz), incl. cable |
Software support |
- 23 Jul 2019: Air2D v1.10 for MacOS and Windows from source code in Max. For multiple sensors or sensor outputs, run multiple instances of the application, each started in its own folder. Requires a digitizer with firmware v7.3 or higher. Use together with Connect (MacOS / Windows).
- 17 Jun 2017: Air2D v1.00 for MacOS and Windows from source code in Max. For multiple sensors or sensor outputs, run multiple instances of the application, each started in its own folder. Requires a digitizer with firmware v7.3 or higher. Use together with Connect (MacOS / Windows).
|
Application notes |
- Make sure the sensor is plugged into the digitizer with the red wire connected to power. Reversing the plug may cause damage to the sensor.
- Requires a digitizer with digital (I2C) ports, eg. USB-microDig or WiDig with firmware v7.3 or higher.
- The default I2C address is 119 (0x77). Both I2C lines have 2.2 kOhm pull-up resistors.
- Our software enables you to use most features of this sensor.
- See the Air2D function description in the firmware documentation for more details about the various methods available in host and standalone mode.
- For more technical specs, and to find out how to access the sensor data in detail, please consult this datasheet.
- To extend the cable, use ExtendCableD-01 and/or ExtendCableD-10.
|