Difference between revisions of "Firmware-811 Commands"
(Copied from Firmware-810 Commands, revision 4027) |
|||
Line 4: | Line 4: | ||
This section describes the messages and commands for resetting the WiDig, obtaining version information, setting the mode of operation (stand-alone or host mode), setting the device ID, setting MIDI out operation, setting running status and obtaining COM port status. These commands have the same effect both in stand-alone and host mode. | This section describes the messages and commands for resetting the WiDig, obtaining version information, setting the mode of operation (stand-alone or host mode), setting the device ID, setting MIDI out operation, setting running status and obtaining COM port status. These commands have the same effect both in stand-alone and host mode. | ||
− | *[[Firmware- | + | *[[Firmware-811 Command-034 |RESET (34, 22h)]] |
− | *[[Firmware- | + | *[[Firmware-811 Command-060 |OUTPUT INIT (60, 3Ch)]] |
− | *[[Firmware- | + | *[[Firmware-811 Command-066 |DUMP FIRMWARE (66, 42h)]] |
− | *[[Firmware- | + | *[[Firmware-811 Command-071 |DUMP VERSION (71, 47h)]] |
− | *[[Firmware- | + | *[[Firmware-811 Command-090 |SET MODE (90, 5Ah)]] |
− | *[[Firmware- | + | *[[Firmware-811 Command-091 |DUMP MODE (91, 5Bh)]] |
− | *[[Firmware- | + | *[[Firmware-811 Command-092 |SET ID (92, 5Ch)]] |
− | *[[Firmware- | + | *[[Firmware-811 Command-032 |SET SOLO (32, 20h)]] |
− | *[[Firmware- | + | *[[Firmware-811 Command-033 |DUMP SOLO (33, 21h)]] |
− | *[[Firmware- | + | *[[Firmware-811 Command-050 |SET MUTE (50, 32h)]] |
− | *[[Firmware- | + | *[[Firmware-811 Command-051 |DUMP MUTE (51, 33h)]] |
− | *[[Firmware- | + | *[[Firmware-811 Command-093 |BLE-MIDI (93, 5Dh)]] |
− | *[[Firmware- | + | *[[Firmware-811 Command-096 |DUMP BLE-MIDI (96, 60h)]] |
− | *[[Firmware- | + | *[[Firmware-811 Command-094 |MIDI STATUS (94, 5Eh)]] |
− | *[[Firmware- | + | *[[Firmware-811 Command-095 |DUMP MIDI STATUS (95, 5Fh)]] |
Line 31: | Line 31: | ||
This section describes the programming protocol commands sent to the WiDig specifically for stand-alone mode. | This section describes the programming protocol commands sent to the WiDig specifically for stand-alone mode. | ||
− | *[[Firmware- | + | *[[Firmware-811 Command-100 |EDIT NAME (100, 64h)]] |
− | *[[Firmware- | + | *[[Firmware-811 Command-101 |DUMP NAME (101, 65h)]] |
− | *[[Firmware- | + | *[[Firmware-811 Command-105 |CLEAR CONFIG (105, 69h)]] |
− | *[[Firmware- | + | *[[Firmware-811 Command-106 |EDIT CONFIG (106, 6Ah)]] |
− | *[[Firmware- | + | *[[Firmware-811 Command-107 |DUMP CONFIG (107, 6Bh)]] |
− | *[[Firmware- | + | *[[Firmware-811 Command-108 |DUMP ALL CONFIG (108, 6Ch)]] |
− | *[[Firmware- | + | *[[Firmware-811 Command-109 |DUMP CONFIG RANGE (109, 6Dh)]] |
Line 45: | Line 45: | ||
This section describes the programming protocol commands sent to the WiDig to configure sensor inputs and actuator outputs that can be used in both host mode and stand-alone mode. | This section describes the programming protocol commands sent to the WiDig to configure sensor inputs and actuator outputs that can be used in both host mode and stand-alone mode. | ||
− | *[[Firmware- | + | *[[Firmware-811 Command-001 |STREAM (1, 01h)]] |
− | *[[Firmware- | + | *[[Firmware-811 Command-011 |DUMP STREAM (11, 0Bh)]] |
− | *[[Firmware- | + | *[[Firmware-811 Command-002 |RES (2, 02h)]] |
− | *[[Firmware- | + | *[[Firmware-811 Command-012 |DUMP RES (12, 0Ch)]] |
− | *[[Firmware- | + | *[[Firmware-811 Command-004 |SAMPLE (4, 04h)]] |
− | *[[Firmware- | + | *[[Firmware-811 Command-003 |INTERVAL (3, 03h)]] |
− | *[[Firmware- | + | *[[Firmware-811 Command-013 |DUMP INTERVAL (13, 0Dh)]] |
− | *[[Firmware- | + | *[[Firmware-811 Command-008 |FUNCTION (8, 08h)]] |
− | *[[Firmware- | + | *[[Firmware-811 Command-018 |DUMP FUNCTION (18, 12h)]] |
− | *[[Firmware- | + | *[[Firmware-811 Command-020 |TABLE ENTRY (20, 14h)]] |
− | *[[Firmware- | + | *[[Firmware-811 Command-030 |DUMP TABLE ENTRY (30, 1Eh)]] |
− | *[[Firmware- | + | *[[Firmware-811 Command-031 |DUMP TABLE (31, 1Fh)]] |
− | *[[Firmware- | + | *[[Firmware-811 Command-047 |SET OUTPUT PULSE (47, 2Fh)]] |
− | *[[Firmware- | + | *[[Firmware-811 Command-048 |SET OUTPUT (48, 30h)]] |
− | *[[Firmware- | + | *[[Firmware-811 Command-049 |SET OUTPUT INIT (49, 31h)]] |
− | *[[Firmware- | + | *[[Firmware-811 Command-057 |DUMP OUTPUT PULSE (57, 39h)]] |
− | *[[Firmware- | + | *[[Firmware-811 Command-058 |DUMP OUTPUT (58, 3Ah)]] |
− | *[[Firmware- | + | *[[Firmware-811 Command-059 |DUMP OUTPUT INIT (59, 3Bh)]] |
− | *[[Firmware- | + | *[[Firmware-811 Command-125 |I2C PORT (125, 7Dh)]] |
− | *[[Firmware- | + | *[[Firmware-811 Command-126 |I2C WRITE (126, 7Eh)]] |
− | *[[Firmware- | + | *[[Firmware-811 Command-124 |I2C WRITE SINGLE (124, 7Ch)]] |
− | *[[Firmware- | + | *[[Firmware-811 Command-127 |I2C READ (127, 7Fh)]] |
− | *[[Firmware- | + | *[[Firmware-811 Command-122 |I2C READ SINGLE (122, 7Ah)]] |
Revision as of 02:45, 16 April 2019
General
This section describes the messages and commands for resetting the WiDig, obtaining version information, setting the mode of operation (stand-alone or host mode), setting the device ID, setting MIDI out operation, setting running status and obtaining COM port status. These commands have the same effect both in stand-alone and host mode.
Standalone Mode
This section describes the programming protocol commands sent to the WiDig specifically for stand-alone mode.
- CLEAR CONFIG (105, 69h)
- EDIT CONFIG (106, 6Ah)
- DUMP CONFIG (107, 6Bh)
- DUMP ALL CONFIG (108, 6Ch)
- DUMP CONFIG RANGE (109, 6Dh)
Dual Mode
This section describes the programming protocol commands sent to the WiDig to configure sensor inputs and actuator outputs that can be used in both host mode and stand-alone mode.