Connect can receive OSC messages to control actuator outputs of a digitizer. See the [[Connect-165_Preferences | preferences]] section to configure Connect for this feature.
  
If the OSC messages match (case insensitive) the format /<digitizer_name>/<output_name> <set_value>, where  digitizer_name is the name of a connected digitizer, and set_value is in {.. -128, 0 .. 127, 128 .. }, the set_value will be mapped to a SET OUTPUT message (see the [[Firmware |firmware]] pages).
+
If the OSC messages match (case insensitive) the format "/<digitizer_name>/<output_name> <set_value>", where  digitizer_name is the name of a connected digitizer, and set_value is in {.. -128, 0 .. 127, 128 .. }, the set_value will be mapped to a SET OUTPUT message (see the [[Firmware |firmware]] pages) as follows:
 
The following OSC messages can be sent:
 
 
{|
 
{|
 
|<b>set_value of OSC Message</b>
 
|<b>set_value of OSC Message</b>
Line 18: Line 17:
 
|}
 
|}
  
For example, "/USB-microDig_0123/Output_01 64" will set an actuator output configured for a PWM actuator to output a pulse with a width that's half of the configured range, so in case of the default PWM configuration (ie. 1 ms range, from 1 to 2 ms) that would be 1.5 ms.  
+
The pulse width value maximum is 125.
  
Sending the same message while the actuator output is configured for an I2C actuator will set the actuator method of the I2C actuator to 64.
+
Example:
 +
 
 +
The OSC message "/USB-microDig_0123/Output_01 62" will set an actuator output configured for a PWM actuator to output a pulse with a width that's half of the configured range, so in case of the default PWM configuration (ie. 1 ms range, from 1 to 2 ms) that would be 1.5 ms.
 +
 
 +
Sending the same message while the actuator output is configured for an I2C actuator will set the actuator method of the I2C actuator to 62.

Latest revision as of 13:41, 16 April 2022

Connect can receive OSC messages to control actuator outputs of a digitizer. See the preferences section to configure Connect for this feature.

If the OSC messages match (case insensitive) the format "/<digitizer_name>/<output_name> <set_value>", where digitizer_name is the name of a connected digitizer, and set_value is in {.. -128, 0 .. 127, 128 .. }, the set_value will be mapped to a SET OUTPUT message (see the firmware pages) as follows:

set_value of OSC Message Action
0 .. 127 enable and set pulse width modulation (if implemented) or set the I2C actuator method as per OSC message value
-128 (or less) or "off" (case insensitive) turn output off
128 (or more) or "on" (case insensitive) turn output on

The pulse width value maximum is 125.

Example:

The OSC message "/USB-microDig_0123/Output_01 62" will set an actuator output configured for a PWM actuator to output a pulse with a width that's half of the configured range, so in case of the default PWM configuration (ie. 1 ms range, from 1 to 2 ms) that would be 1.5 ms.

Sending the same message while the actuator output is configured for an I2C actuator will set the actuator method of the I2C actuator to 62.