Connect can receive OSC messages to control actuator outputs of a digitizer. See the preferences section to configure Connect for this feature.

If the OSC messages match (case insensitive) the format "/<digitizer_name>/<output_name> <set_value>", where digitizer_name is the name of a connected digitizer, and set_value is in {.. -128, 0 .. 127, 128 .. }, the set_value will be mapped to a SET OUTPUT message (see the firmware pages) as follows:

set_value of OSC Message Action
0 .. 127 enable and set pulse width modulation (if implemented) or set the I2C actuator method as per OSC message value
-128 (or less) or "off" (case insensitive) turn output off
128 (or more) or "on" (case insensitive) turn output on

The pulse width value maximum is 125.

Example:

The OSC message "/USB-microDig_0123/Output_01 62" will set an actuator output configured for a PWM actuator to output a pulse with a width that's half of the configured range, so in case of the default PWM configuration (ie. 1 ms range, from 1 to 2 ms) that would be 1.5 ms.