Connect-165 OSC Input
OSC messages should be sent to localhost (127.0.0.1). The Port field can be set to any number but note that many port numbers are used by applications. If the port is unavailable, the text "in use" will appear next to the port. In that case, check whether the port number is in use by another application or use another port. The default port number 9999 set by Connect is not guaranteed to be conflict-free.
If the OSC messages match (case insensitive) the format /<digitizer_name>/<output_name> <set_value>, where digitizer_name is the name of a connected digitizer, and set_value is in {.. -128, 0 .. 127, 128 .. }, the set_value will be mapped to a SET OUTPUT message (see the firmware pages).
The following OSC messages can be sent:
set_value of OSC Message | Action |
0 .. 127 | enable and set pulse width modulation (if implemented) or set the I2C actuator method as per OSC message value |
-128 (or less) or "off" (case insensitive) | turn output off |
128 (or more) or "on" (case insensitive) | turn output on |
Example:
"/USB-microDig_0123/Output_01 64" will set an actuator output configured for a PWM actuator to output a pulse with a width that's half of the configured range, so in case of the default PWM configuration (ie. 1 ms range, from 1 to 2 ms) that would be 1.5 ms.
Sending the same message while the actuator output is configured for an I2C actuator will set the actuator method of the I2C actuator to 64.