Firmware-72 Command-107

From I-CubeX Wiki
Jump to: navigation, search

DUMP CONFIG (107, 6Bh)

The DUMP CONFIG command is used to obtain the current settings of the USB-microDig. Upon completion of the command the USB-microDig sends out the CONFIG message.

The USB-microDig will send out the configuration of a USB-microDig sensor input when using the DUMP CONFIG command with the following [BODY]:

00000001: 1; configuration number
00000aaa: aaa = [0..7]; sensor input number

The Digitizer will send out the configuration of each USB-microDig binary output as well as the sample interval value when using the DUMP CONFIG command with a special value for the 2nd data byte in the [BODY]:

00000001: 1; configuration number
01111111: 127; actuator outputs flag