Firmware-811 Message-037
MIDI COM (37, 25h)
The MIDI COM message indicates a MIDI communications error. The [BODY] of the MIDI COM message indicates the type of error encountered.
The [BODY] of the reset message:
0xxxxxxx: | xxxxxxx = 90 (5Ah); configuration setting error as a result of a received command |
xxxxxxx = 92 (5Ch); MIDI protocol error / Invalid Command (invalid command number, bad number of arguments or invalid arguments in command) | |
xxxxxxx = 94 (5Eh); MIDI byte has been scrambled | |
xxxxxxx = 95 (5Fh); receive buffer is full, data may be lost (too much MIDI data is being sent to the WiDig too quickly) |
Example:
- 240, 125, 0 {DEV}, 37 {MIDI COM}, 95 {DATA}, 247 (F0h, 7Dh, 00h, 25h, 5Fh, F7h) This message indicates that too much MIDI data is being sent to the WiDig too quickly.