Firmware-812 Command-111
LOW POWER (111, 6Fh)
This command sets the WiDig to dim the LEDs. Upon completion of the command the WiDig sends out the LOW POWER message. To get the LED status, send the command without body.
To set the LEDs, the [BODY] of the LOW POWER command should be as follows:
0xxxxxxx: | xxxxxxx = 64; turn LEDs on |
xxxxxxx = 96; dim LEDs |