Firmware-830 Command-060
OUTPUT INIT (60, 3Ch)
The OUTPUT INIT command set the WiDig’s actuator outputs to their power-up or reset status. The OUTPUT INIT command reloads the settings stored in non-volatile memory into the volatile memory for operational use. Non-volatile memory remains unchanged. In host mode no settings are loaded from non-volatile memory and the configuration is set to defaults. The OUTPUT INIT command is always executed following a power-up. Upon completion of the OUTPUT INIT command the same message is sent out by the WiDig.
There is no [BODY] associated with this command.
Example:
- 240, 125, 0 {DEV}, 60 {OUTPUT INIT}, 247 (F0h, 7Dh, 00h, 3Ch, F7h)
Initial values
Actuator activation status: | retrieved from non-volatile memory (see SET OUTPUT INIT command) |
Actuator PWM status: | retrieved from non-volatile memory (see SET OUTPUT INIT command) |
Actuator pulse interval: | retrieved from non-volatile memory (see SET OUTPUT PULSE command) |
Actuator pulse width range: | retrieved from non-volatile memory (see SET OUTPUT PULSE command) |