Firmware-830 Command-060

From I-CubeX Wiki
Jump to: navigation, search

OUTPUT INIT (60, 3Ch)

The OUTPUT INIT command set the WiDig’s actuator outputs to their power-up or reset status. The OUTPUT INIT command reloads the settings stored in non-volatile memory into the volatile memory for operational use. Non-volatile memory remains unchanged. In host mode no settings are loaded from non-volatile memory and the configuration is set to defaults. The OUTPUT INIT command is always executed following a power-up. Upon completion of the OUTPUT INIT command the same message is sent out by the WiDig.

There is no [BODY] associated with this command.

Example:

240, 125, 0 {DEV}, 60 {OUTPUT INIT}, 247 (F0h, 7Dh, 00h, 3Ch, F7h)


Initial values

Actuator activation status: retrieved from non-volatile memory (see SET OUTPUT INIT command)
Actuator PWM status: retrieved from non-volatile memory (see SET OUTPUT INIT command)
Actuator pulse interval: retrieved from non-volatile memory (see SET OUTPUT PULSE command)
Actuator pulse width range: retrieved from non-volatile memory (see SET OUTPUT PULSE command)