Difference between revisions of "Firmware-73 Commands"
Line 16: | Line 16: | ||
*[[Firmware-73 Command-032 |MUTE (32, 20h)]] | *[[Firmware-73 Command-032 |MUTE (32, 20h)]] | ||
*[[Firmware-73 Command-050 |SET MUTE (50, 32h)]] | *[[Firmware-73 Command-050 |SET MUTE (50, 32h)]] | ||
+ | *[[Firmware-73 Command-051 |DUMP MUTE (51, 33h)]] | ||
*[[Firmware-73 Command-093 |MIDI OUT (93, 5Dh)]] | *[[Firmware-73 Command-093 |MIDI OUT (93, 5Dh)]] | ||
Line 43: | Line 44: | ||
*[[Firmware-73 Command-001 |STREAM (1, 01h)]] | *[[Firmware-73 Command-001 |STREAM (1, 01h)]] | ||
+ | *[[Firmware-73 Command-001 |DUMP STREAM (11, 0Bh)]] | ||
*[[Firmware-73 Command-002 |RES (2, 02h)]] | *[[Firmware-73 Command-002 |RES (2, 02h)]] | ||
+ | *[[Firmware-73 Command-002 |DUMP RES (12, 0Ch)]] | ||
*[[Firmware-73 Command-004 |SAMPLE (4, 04h)]] | *[[Firmware-73 Command-004 |SAMPLE (4, 04h)]] | ||
Line 50: | Line 53: | ||
*[[Firmware-73 Command-008 |FUNCTION (8, 08h)]] | *[[Firmware-73 Command-008 |FUNCTION (8, 08h)]] | ||
− | *[[Firmware-73 Command-018 | | + | *[[Firmware-73 Command-018 |DUMP FUNCTION (18, 12h)]] |
*[[Firmware-73 Command-020 |TABLE ENTRY (20, 14h)]] | *[[Firmware-73 Command-020 |TABLE ENTRY (20, 14h)]] | ||
− | *[[Firmware-73 Command-021 | | + | *[[Firmware-73 Command-021 |DUMP TABLE ENTRY (21, 15h)]] |
− | *[[Firmware-73 Command-031 | | + | *[[Firmware-73 Command-031 |DUMP TABLE (31, 1Fh)]] |
*[[Firmware-73 Command-047 |SET OUTPUT PULSE (47, 2Fh)]] | *[[Firmware-73 Command-047 |SET OUTPUT PULSE (47, 2Fh)]] | ||
*[[Firmware-73 Command-048 |SET OUTPUT (48, 30h)]] | *[[Firmware-73 Command-048 |SET OUTPUT (48, 30h)]] | ||
*[[Firmware-73 Command-049 |SET OUTPUT INIT (49, 31h)]] | *[[Firmware-73 Command-049 |SET OUTPUT INIT (49, 31h)]] | ||
− | *[[Firmware-73 Command-057 | | + | *[[Firmware-73 Command-057 |DUMP OUTPUT PULSE (57, 39h)]] |
− | *[[Firmware-73 Command-058 | | + | *[[Firmware-73 Command-058 |DUMP OUTPUT (58, 3Ah)]] |
− | *[[Firmware-73 Command-059 | | + | *[[Firmware-73 Command-059 |DUMP OUTPUT INIT (59, 3Bh)]] |
*[[Firmware-73 Command-125 |I2C PORT (125, 7Dh)]] | *[[Firmware-73 Command-125 |I2C PORT (125, 7Dh)]] |
Revision as of 03:26, 20 November 2016
General
This section describes the messages and commands for resetting the USB-microDig, obtaining version information, setting the mode of operation (stand-alone or host mode), setting the device ID, setting MIDI out operation, setting running status and obtaining COM port status. These commands have the same effect both in stand-alone and host mode.
Standalone Mode
This section describes the programming protocol commands sent to the USB-microDig specifically for stand-alone mode.
Dual Mode
This section describes the programming protocol commands sent to the USB-microDig to configure sensor inputs and actuator outputs that can be used in both host mode and stand-alone mode.