Difference between revisions of "Firmware-63 Commands"

From I-CubeX Wiki
Jump to: navigation, search
(Created page with "Since many firmware 6.2 commands are the same as used in firmware 7.2, reference is made to firmware 7.2 information where applicable. ==General== This section describes the...")
 
 
Line 6: Line 6:
  
 
*[[Firmware-73 Command-034 |RESET (34, 22h)]]
 
*[[Firmware-73 Command-034 |RESET (34, 22h)]]
 +
*[[Firmware-73 Command-060 |OUTPUT INIT (60, 3Ch)]]
  
 
*[[Firmware-73 Command-071 |DUMP VERSION (71, 47h)]]
 
*[[Firmware-73 Command-071 |DUMP VERSION (71, 47h)]]
Line 14: Line 15:
 
*[[Firmware-73 Command-092 |SET ID (92, 5Ch)]]
 
*[[Firmware-73 Command-092 |SET ID (92, 5Ch)]]
  
*[[Firmware-73 Command-032 |MUTE (32, 20h)]]
+
*[[Firmware-73 Command-032 |TOGGLE MUTE (32, 20h)]]
 
*[[Firmware-73 Command-050 |SET MUTE (50, 32h)]]
 
*[[Firmware-73 Command-050 |SET MUTE (50, 32h)]]
 +
*[[Firmware-73 Command-051 |DUMP MUTE (51, 33h)]]
  
*[[Firmware-73 Command-094 |MIDI RUNNING STATUS (94, 5Eh)]]
+
*[[Firmware-73 Command-094 |MIDI STATUS (94, 5Eh)]]
*[[Firmware-73 Command-095 |DUMP RUNNING STATUS (95, 5Fh)]]
+
*[[Firmware-73 Command-095 |DUMP MIDI STATUS (95, 5Fh)]]
  
 
*[[Firmware-63 Command-111 |LOW POWER LEVEL (111, 6Fh)]]
 
*[[Firmware-63 Command-111 |LOW POWER LEVEL (111, 6Fh)]]
Line 41: Line 43:
  
 
*[[Firmware-73 Command-001 |STREAM (1, 01h)]]
 
*[[Firmware-73 Command-001 |STREAM (1, 01h)]]
 +
*[[Firmware-73 Command-011 |DUMP STREAM (11, 0Bh)]]
 
*[[Firmware-73 Command-002 |RES (2, 02h)]]
 
*[[Firmware-73 Command-002 |RES (2, 02h)]]
 +
*[[Firmware-73 Command-012 |DUMP RES (12, 0Ch)]]
 
*[[Firmware-73 Command-004 |SAMPLE (4, 04h)]]
 
*[[Firmware-73 Command-004 |SAMPLE (4, 04h)]]
  
 
*[[Firmware-73 Command-003 |INTERVAL (3, 03h)]]
 
*[[Firmware-73 Command-003 |INTERVAL (3, 03h)]]
*[[Firmware-73 Command-013 |SEND INTERVAL (13, 0Dh)]]
+
*[[Firmware-73 Command-013 |DUMP INTERVAL (13, 0Dh)]]
  
 
*[[Firmware-73 Command-008 |FUNCTION (8, 08h)]]
 
*[[Firmware-73 Command-008 |FUNCTION (8, 08h)]]
*[[Firmware-73 Command-018 |SEND FUNCTION (18, 12h)]]
+
*[[Firmware-73 Command-018 |DUMP FUNCTION (18, 12h)]]
 +
 
 +
*[[Firmware-73 Command-047 |SET OUTPUT PULSE (47, 2Fh)]]
 +
*[[Firmware-73 Command-048 |SET OUTPUT (48, 30h)]]
 +
*[[Firmware-73 Command-049 |SET OUTPUT INIT (49, 31h)]]
 +
*[[Firmware-73 Command-057 |DUMP OUTPUT PULSE (57, 39h)]]
 +
*[[Firmware-73 Command-058 |DUMP OUTPUT (58, 3Ah)]]
 +
*[[Firmware-73 Command-059 |DUMP OUTPUT INIT (59, 3Bh)]]
  
 
*[[Firmware-73 Command-125 |I2C PORT (125, 7Dh)]]
 
*[[Firmware-73 Command-125 |I2C PORT (125, 7Dh)]]

Latest revision as of 04:19, 29 November 2016

Since many firmware 6.2 commands are the same as used in firmware 7.2, reference is made to firmware 7.2 information where applicable.

General

This section describes the messages and commands for resetting the Wi-microDig, obtaining version information, setting the mode of operation (stand-alone or host mode), setting the device ID, setting MIDI out operation, setting running status and obtaining the Bluetooth port status. These commands have the same effect both in stand-alone and host mode.


Standalone Mode

This section describes the programming protocol commands sent to the USB-microDig specifically for stand-alone mode.


Dual Mode

This section describes the programming protocol commands sent to the USB-microDig to configure sensor inputs and actuator outputs that can be used in both host mode and stand-alone mode.