- 23:54, 6 March 2022 (diff | hist) . . (+382) . . N Firmware-820 Message-033 (Created page with "==SOLO (33, 21h)== This message contains the WiDig SOLO status. See the SET SOLO command for more information on the SOLO feature. The [BODY] o...") (current)
- 23:54, 6 March 2022 (diff | hist) . . (empty) . . Firmware-830 Message-033 (Copied from Firmware-820 Message-033, revision 5763)
- 23:54, 6 March 2022 (diff | hist) . . (+401) . . N Firmware-820 Message-051 (Created page with "==MUTE (51, 33h)== This message contains the WiDig MUTE status. See the SET MUTE command for more information on the MUTE feature. The [BODY] o...") (current)
- 23:54, 6 March 2022 (diff | hist) . . (empty) . . Firmware-830 Message-051 (Copied from Firmware-820 Message-051, revision 5762)
- 23:53, 6 March 2022 (diff | hist) . . (+519) . . N Firmware-820 Message-091 (Created page with "==MODE (91, 5Bh)== This message contains the WiDig operation mode. The WiDig can function in host mode (for use with Max/MSP for example), or in stand-alone mode (with most M...") (current)
- 23:53, 6 March 2022 (diff | hist) . . (empty) . . Firmware-830 Message-091 (Copied from Firmware-820 Message-091, revision 5761)
- 23:52, 6 March 2022 (diff | hist) . . (+620) . . N Firmware-820 Message-035 (Created page with "==RESET ACK (35, 23h)== The RESET ACK message provides acknowledgement that the WiDig has been reset. A reset is performed when the WiDig is powered up and that COM port conn...") (current)
- 23:52, 6 March 2022 (diff | hist) . . (empty) . . Firmware-830 Message-035 (Copied from Firmware-820 Message-035, revision 5760)
- 23:51, 6 March 2022 (diff | hist) . . (0) . . Firmware-820 Messages
- 23:50, 6 March 2022 (diff | hist) . . (+380) . . N Firmware-820 Command-111 (Created page with "==LOW POWER (111, 6Fh)== This command sets the WiDig to dim the LEDs. Upon completion of the command the WiDig sends out the LOW POWER message....")
- 23:50, 6 March 2022 (diff | hist) . . (0) . . Firmware-820 Commands (→General)
- 23:49, 6 March 2022 (diff | hist) . . (+402) . . N Firmware-820 Command-095 (Created page with "==DUMP MIDI CONFIG (95, 5Fh)== This command requests the WiDig to send out whether running status, active sensing and sampling loop marking are enabled or not. See the Firm...") (current)
- 23:49, 6 March 2022 (diff | hist) . . (empty) . . Firmware-830 Command-095 (Copied from Firmware-820 Command-095, revision 5756)
- 23:48, 6 March 2022 (diff | hist) . . (+2,494) . . N Firmware-820 Command-094 (Created page with "==MIDI CONFIG (94, 5Eh)== This command enables / disables MIDI running status and active sensing, and the sending of a MIDI byte each time the WiDig's sampling loop starts....") (current)
- 23:48, 6 March 2022 (diff | hist) . . (empty) . . Firmware-830 Command-094 (Copied from Firmware-820 Command-094, revision 5755) (current)
- 23:47, 6 March 2022 (diff | hist) . . (+353) . . N Firmware-820 Command-096 (Created page with "==DUMP MIDI OUT (96, 60h)== This command requests the WiDig to send out the BLE-MIDI (MIDI via Bluetooth Low Energy) status. See the BLE-MIDI command for more information abo...") (current)
- 23:47, 6 March 2022 (diff | hist) . . (empty) . . Firmware-830 Command-096 (Copied from Firmware-820 Command-096, revision 5754)
- 23:46, 6 March 2022 (diff | hist) . . (+489) . . N Firmware-820 Command-093 (Created page with "==BLE-MIDI (93, 5Dh)== This command sets the BLE-MIDI (MIDI via Bluetooth Low Energy) status of the WiDig. Upon first use, BLE-MIDI is enabled. The BLE-MIDI command configure...") (current)
- 23:46, 6 March 2022 (diff | hist) . . (empty) . . Firmware-830 Command-093 (Copied from Firmware-820 Command-093, revision 5753)
- 23:45, 6 March 2022 (diff | hist) . . (+298) . . N Firmware-820 Command-051 (Created page with "==DUMP MUTE (51, 33h)== This command requests the WiDig to send out the MUTE status. See the SET MUTE command for more information on the MUTE feature. Upon completion of the...") (current)
- 23:45, 6 March 2022 (diff | hist) . . (empty) . . Firmware-830 Command-051 (Copied from Firmware-820 Command-051, revision 5752)
- 23:45, 6 March 2022 (diff | hist) . . (+682) . . N Firmware-820 Command-050 (Created page with "==SET MUTE (50, 32h)== The SET MUTE command stops the sampling of all sensor inputs. It can be used in both modes of operation (stand-alone, host). After completion of the SE...") (current)
- 23:45, 6 March 2022 (diff | hist) . . (empty) . . Firmware-830 Command-050 (Copied from Firmware-820 Command-050, revision 5751) (current)
- 23:44, 6 March 2022 (diff | hist) . . (+298) . . N Firmware-820 Command-033 (Created page with "==DUMP SOLO (33, 21h)== This command requests the WiDig to send out the SOLO status. See the SET SOLO command for more information on the SOLO feature. Upon completion of the...") (current)
- 23:44, 6 March 2022 (diff | hist) . . (empty) . . Firmware-830 Command-033 (Copied from Firmware-820 Command-033, revision 5750)
- 23:43, 6 March 2022 (diff | hist) . . (+1,057) . . N Firmware-820 Command-032 (Created page with "==SET SOLO (32, 20h)== The SET SOLO command stops the processing of all sensor inputs except one so that the user can easily utilise the MIDI learn capability of a MIDI devic...") (current)
- 23:43, 6 March 2022 (diff | hist) . . (empty) . . Firmware-830 Command-032 (Copied from Firmware-820 Command-032, revision 5749) (current)
- 23:42, 6 March 2022 (diff | hist) . . (+578) . . N Firmware-820 Command-092 (Created page with "==SET ID (92, 5Ch)== The SET ID command sets the system exclusive device ID of the WiDig, enabling use of up to 128 WiDigs in one MIDI chain. The SET ID command can be sent w...") (current)
- 23:42, 6 March 2022 (diff | hist) . . (empty) . . Firmware-830 Command-092 (Copied from Firmware-820 Command-092, revision 5748) (current)
- 23:41, 6 March 2022 (diff | hist) . . (+525) . . N Firmware-820 Command-091 (Created page with "==DUMP MODE (91, 5Bh)== This command requests the WiDig to send out its current mode of operation, which may be different from the mode setting stored in non-volatile memory....") (current)
- 23:41, 6 March 2022 (diff | hist) . . (empty) . . Firmware-830 Command-091 (Copied from Firmware-820 Command-091, revision 5747)
- 23:41, 6 March 2022 (diff | hist) . . (+758) . . N Firmware-820 Command-090 (Created page with "==SET MODE (90, 5Ah)== This command sets the WiDig operation mode. When switching the mode of operation, all settings stored in non-volatile memory remain unchanged but all s...") (current)
- 23:41, 6 March 2022 (diff | hist) . . (empty) . . Firmware-830 Command-090 (Copied from Firmware-820 Command-090, revision 5746)
- 23:40, 6 March 2022 (diff | hist) . . (+343) . . N Firmware-820 Command-071 (Created page with "==DUMP VERSION (71, 47h)== This command requests the WiDig to send out its serial number and firmware version number. Upon completion of the command the WiDig sends out the [...") (current)
- 23:40, 6 March 2022 (diff | hist) . . (empty) . . Firmware-830 Command-071 (Copied from Firmware-820 Command-071, revision 5745)
- 23:39, 6 March 2022 (diff | hist) . . (0) . . Firmware-820 Command-034 (current)
- 23:39, 6 March 2022 (diff | hist) . . (empty) . . Firmware-830 Command-034 (Copied from Firmware-820 Command-034, revision 5744)
- 23:39, 6 March 2022 (diff | hist) . . (+279) . . N Firmware-820 Command-066 (Created page with "==DUMP FIRMWARE (66, 42h)== This command requests the WiDig to send out its firmware version number and firmware build date. Upon completion of the command the WiDig sends ou...")
- 23:38, 6 March 2022 (diff | hist) . . (+1,012) . . N Firmware-820 Command-060 (Created page with "==OUTPUT INIT (60, 3Ch)== The OUTPUT INIT command set the WiDig’s actuator outputs to their power-up or reset status. Non-volatile memory remains unchanged. The OUTPUT INIT...") (current)
- 23:38, 6 March 2022 (diff | hist) . . (empty) . . Firmware-830 Command-060 (Copied from Firmware-820 Command-060, revision 5742)
- 23:37, 6 March 2022 (diff | hist) . . (+3,420) . . N Firmware-820 Command-034 (Created page with "==RESET (34, 22h)== The RESET command resets the WiDig, i.e. all internal circuitry and system variables stored in volatile memory are re-initialized. Non-volatile memory rem...")
- 23:37, 6 March 2022 (diff | hist) . . (-1) . . Firmware-820 Commands (→General)
- 01:19, 6 March 2022 (diff | hist) . . (+89) . . Firmware-812 Command-111 (→LOW POWER (111, 6Fh)) (current)
- 16:23, 5 March 2022 (diff | hist) . . (+1) . . EditorX-82 Digitizer
- 16:23, 5 March 2022 (diff | hist) . . (+176) . . EditorX-82 Digitizer (→Communication Method)
- 16:19, 5 March 2022 (diff | hist) . . (+105) . . Connect-155 Digitizer View (current)
- 16:19, 5 March 2022 (diff | hist) . . (empty) . . Connect-160 Digitizer View (Copied from Connect-155 Digitizer View, revision 5736)
- 16:16, 5 March 2022 (diff | hist) . . (+105) . . Connect-165 Digitizer View (current)
- 16:16, 5 March 2022 (diff | hist) . . (empty) . . Connect-170 Digitizer View (Copied from Connect-165 Digitizer View, revision 5735)
- 16:12, 5 March 2022 (diff | hist) . . (+5) . . EditorX-82 System Requirements
(newest | oldest) View (newer 50 | older 50) (20 | 50 | 100 | 250 | 500)